Installed right. Kept running.

Installation, planned maintenance and breakdown support for Winchester sets and most other makes of diesel generator.

01 / Installation & commissioning

From empty plot to power-on.

A generator is only as reliable as its installation. We handle the full scope so nothing falls between contractors.

  • Site survey and load assessment
  • Foundation and plinth drawings
  • ATS / changeover panel supply and wiring
  • Power and control cabling, earthing
  • Exhaust, ventilation and fuel line routing
  • Commissioning with full load bank test and handover report
Generator installed on a concrete plinth at an industrial site
FIG. 03 — Installation on prepared plinth
02 / Maintenance contracts (AMC)

Choose your level of cover.

Plans are priced per set, based on size and running hours. Click a plan to see what it includes.

Essential

For standby sets with low running hours.

    Every plan includes

    • Visual inspection, fluid and battery checks
    • Oil, filter and coolant service at set intervals
    • Controller and ATS function test
    • Written service report after every visit
    • Priority breakdown response
    Get an AMC quote
    03 / Support services
    24/7

    Breakdown repair

    Round-the-clock fault response for all diesel generator makes. Diagnostics, repair and temporary power if needed.

    +971 58 808 3232
    PARTS

    Spare parts

    Filters, belts, batteries, sensors, controllers and AVRs. Genuine and approved parts sourced to order.

    Request parts
    TEST

    Load bank testing

    Resistive load testing to prove capacity, burn off wet-stacking and meet authority or insurer requirements.

    Book a test
    UPGRADE

    Retrofits

    Controller upgrades, remote monitoring, canopy refurbishment and ATS replacement for older sets.

    Discuss a retrofit
    FUEL

    Fuel management

    Fuel polishing, tank cleaning and level monitoring to stop contaminated fuel causing failures.

    Ask about fuel care
    RELOCATE

    Relocation

    Safe disconnection, lifting, transport and reinstallation when a set needs to move.

    Plan a move
    Service FAQ

    Good to know.

    Do you service generators you didn't supply?
    Yes. We maintain most common makes of diesel generator. We'll inspect the set first and tell you honestly about its condition.
    How often should a standby generator be serviced?
    Typically every 6 months or 250 running hours, whichever comes first, with a weekly or monthly test run. High-use or critical sets need more frequent visits.
    Why does my generator need a load bank test?
    Standby sets often run lightly loaded, which leads to carbon build-up ("wet-stacking"). A load bank test runs the set at its rated load to prove it will perform when needed.
    Can I monitor my generator remotely?
    Most modern controllers support remote monitoring. We can retrofit a module so you get alerts for faults, low fuel and mains failure.